12 resultados para Device design

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this experiment was to evaluate effects of treatments with intravaginal progesterone (N) device and/or 48 h temporary weaning (TW) on reproductive performance of postpartum anestrous crossbred Angus x Nelore cows, throughout the breeding season (BS). Anestrous cows (n = 296; 53 5 DPP, body condition score between 2.5 and 3.5, on a 1-5 scale) were assigned randomly to four treatments (2 x 2 factorial design): (1) Control Group (no treatment; n = 73); (2) TW Group (48 h TW beginning on day 0 of BS; n = 70); (3) P4 Group (Intravaginal P4 device between days -7 and 0 of BS; n = 73); and (4) P4+TW Group (Intravaginal P4 device between days -7 and 0 of BS followed by 48h TW; n=70). on day 0 of BS (when P4 devices were removed and TW was initiated), cows had their ovaries evaluated by ultrasonography aiming to evaluate size of the largest follicle. Signs of behavioral estrus were observed twice a day (morning and evening), between days 0 and 25 of BS, and cows observed in estrus were inseminated 12 h later. Between days 26 and 80 of BS, cows were submitted to natural service. Pregnancy diagnosis was conducted by transrectal ultrasonography on days 32 and 53 (pregnancies by AI) and 114 (pregnancies by natural service). Rates of detection of estrus during the first 3 days and within 25 days of BS were greater in cows receiving TW (45.0% compared with 9.6% and 50.0% compared with 29.5%, respectively; P < 0.01). Conception rate in cows inseminated in the first 3 days of BS was greater in cows treated with P4 (54.8% compared with 11.1 %; P < 0.01). Combining P4+TW increased pregnancy rate in the first 3 days (Control: 1.4%, TW: 4.3%, P4: 8.2% and P4+TW: 24.3%; P < 0.01) and in 25 days of BS (Control: 10.9%, TW: 7.1%, P4: 13.7% and P4+TW: 28.6%; P < 0.05). Pregnancy rate at the end of BS did not differ among treatment groups. In conclusion, TW alone increased estrous behavior whereas P4 alone benefited conception. Combining P4 with TW improved pregnancy rate with direct benefits to behavioral estrus and conception. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Standardization of measurements for marginal fit of castings is critical. This study describes the fabrication of a device that allowed fixation of specimens on a Toolmakers microscope with identical conditions according to tri-dimensional positioning of specimens, measuring location, and seating force. The device also allows mapping of the marginal discrepancies on the entire marginal perimeter of the tooth preparation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We develop an economic model for X̄ control charts having all design parameters varying in an adaptive way, that is, in real time considering current sample information. In the proposed model, each of the design parameters can assume two values as a function of the most recent process information. The cost function is derived and it provides a device for optimal selection of the design parameters. Through a numerical example one can foresee the savings that the developed model possibly provides. © 2001 Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the analysis, design, simulation, and experimental results for a high frequency high Power-Factor (PF) AC (Alternate Current) voltage regulator, using a Sepic converter as power stage. The control technique employed to impose a sinusoidal input current waveform, with low Total Harmonic Distortion (THD), is the sinusoidal variable hysteresis control. The control technique was implemented in a FPGA (Field Programmable Gate Array) device, using a Hardware Description Language (VHDL). Through the use of the proposed control technique, the AC voltage regulator performs active power-factor correction, and low THD in the input current, for linear and non-linear loads, satisfying the requirements of the EEC61000-3-2 standards. Experimental results from an example prototype, designed for 300W of nominal output power, 50kHz (switching frequency), and 127Vrms of nominal input and output voltages, are presented in order to validate the proposed AC regulator. © 2005 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, a mathematical model is derived via Lagrange's Equation for a shear building structure that acts as a foundation of a non-ideal direct current electric motor, controlled by a mass loose inside a circular carving. Non-ideal sources of vibrations of structures are those whose characteristics are coupled to the motion of the structure, not being a function of time only as in the ideal case. Thus, in this case, an additional equation of motion is written, related to the motor rotation, coupled to the equation describing the horizontal motion of the shear building. This kind of problem can lead to the so-called Sommerfeld effect: steady state frequencies of the motor will usually increase as more power (voltage) is given to it in a step-by-step fashion. When a resonance condition with the structure is reached, the better part of this energy is consumed to generate large amplitude vibrations of the foundation without sensible change of the motor frequency as before. If additional increase steps in voltage are made, one may reach a situation where the rotor will jump to higher rotation regimes, no steady states being stable in between. As a device of passive control of both large amplitude vibrations and the Sommerfeld effect, a scheme is proposed using a point mass free to bounce back and forth inside a circular carving in the suspended mass of the structure. Numerical simulations of the model are also presented Copyright © 2007 by ASME.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Previous studies have shown that membrane elevation results in predictable bone formation in the maxillary sinus provided that implants can be placed as tent poles. In situations with an extremely thin residual crest which impairs implant placement, it is possible that a space-making device can be used under the sinus membrane to promote bone formation prior to placement of implants. Purpose: The present study was conducted to test the hypothesis that the use of a space-making device for elevation of the sinus membrane will result in predictable bone formation at the maxillary sinus floor to allow placement of dental implants. Materials and Methods: Eight tufted capuchin primates underwent bilateral sinus membrane elevation surgery, and a bioresorbable space-making device, about 6 mm wide and 6 mm in height, was placed below the elevated membrane on the sinus floor. An oxidized implant (Nobel Biocare AB, Gothenburg, Sweden) was installed in the residual bone protruding into the created space at one side while the other side was left without an implant. Four animals were sacrificed after 6 months of healing. The remaining four animals received a second implant in the side with a space-making device only and followed for another 3 months before sacrifice. Implant stability was assessed through resonance frequency analysis (RFA) using the Osstell™ (Osstell AB, Gothenburg, Sweden) at installation, 6 months and 9 months after the first surgery. The bone-implant contact (BIC) and bone area inside the threads (BA) were histometrically evaluated in ground sections. Results: Histologically there were only minor or no signs of bone formation in the sites with a space-making device only. Sites with simultaneous implant placement showed bone formation along the implant surface. Sites with delayed implant placement showed minor or no bone formation and/or formation of a dense fibrous tissue along the apical part of the implant surface. In the latter group the apical part of the implant was not covered with the membrane but protruded into the sinus cavity. Conclusions: The use of a space-making device, with the design used in the present study, does not result in bone formation at the sinus floor. However, membrane elevation and simultaneous placement of the device and an implant does result in bone formation at the implant surface while sites with implants placed 6 months after membrane elevation show only small amounts of bone formation. It is suggested that lack of stabilization of the device and/or a too extensive elevation of the membrane may explain the results. © 2009, Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the paper the improvement of a traditional structure of a microprogrammed controller with sharing codes is discussed. The idea is based on the modification of internal modules and connections of the device. Such a solution permits to reduce the number of embedded memories needed for implementation of the microprogrammed controller on programmable structures, especially FPGAs. © 2011 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The design of the ParalAB device facilitates transfer of the path of insertion from the diagnostic cast to the mouth quickly and efficiently.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS